Ammonia Scrubber
The scrubbing of ammonia from the air stream can be successfully done with the use of a wet scrubber. A correctly designed scrubbing tower can offer removal efficiencies of +99%.
Q-Pac packing is used to provide a plug resistant and low pressure drop option to this problem.
Design Example:
Ammonia is release into the air from process. The fugitive fume is capturing a transported to a scrubber column. Ammonia is a known irritant and requires removal from the workplace before it gets into the workers respiratory system.
Design considerations are as follows:-
Air flow:
Peak Inlet Concentration:
Scrubbing Efficiency: |
16,300 Nm3/hr
95 ppmv
>1 ppmv |
Recommendations:-
Tower diameter:
Superficial Gas Velocity:
Packing:
Packed Depth:
Scrubbing Liquor:
Recirculation Rate:
Liquid flux:
Q-PAC Pressure Drop:
Scrubbing Efficiency: |
1500 mm
2,8 m/sec
Q-PAC® in polypropylene
1250 mm
water with H2SO4 added
22 m3/hr
12.5 m3/m2-h
1.5 mbar
99%+ |
Please consult with S G Plastic Construction regarding the design requirements of your specific project. No warranty is given or implied with this design example. All designs that are v
reviewed